Recall Z-2279-2012— Mindray DS USA, Inc. d.b.a. Mindray North America
Class II · Terminated
Class II FDA medical device recall by Mindray DS USA, Inc. d.b.a. Mindray North America, initiated 2012-05-07, terminated 2013-07-17. It names one FDA 510(k) clearance: K102004. Product: V Series Patient Monitors; Mindray DS USA, Inc. Product Usage: The V Series Monitor is intended for intra hospital use under the direct supervision of a licensed healthcare practitioner. The indications for Use for the V Series include the monitoring of the following human physiological parameters: ECG waveform derived from 3, 5, 6 and 12 lead measurements; Heart Rate; Pulse Oximetry (SpO2); ST Segment Analysis; Arrhythmia Detection; Non Invasive Blood Pressure (NIBP); Invasive Blood Pressure (IBP); Cardiac Output (CO); Respiratory Gasses; Respiration Rate; and Temperature. The V Series Monitor has the capability of performing IV Drug and Hemodynamic Calculations and interfacing with network devices. The target populations are adult, pediatric and neonate with the exception of: Arrhythmia detection and ST Segment Analysis, for which the target populations are adult and pediatric only; IV Drug Calculations for which the target population is adult only; and Cardiac Output for which the target population is adult and pediatric only.. Reason: Mindray has identified two software anomalies contained in the V Series Monitoring System. There have been no reports of injuries associated with these anomalies. These anomalies affect V Series Systems distributed between September 31, 2010 and January 9, 2012..
- Recalling firm
- Mindray DS USA, Inc. d.b.a. Mindray North America
- Classification
- Class II
- Status
- Terminated
- Initiated
- 2012-05-07
- Terminated
- 2013-07-17
- Firm location
- Mahwah, NJ, United States
510(k) clearances named in this recall
1 on FDA's recordK-numbers as listed on FDA's Recall Enterprise System record for this event (openFDA device/recall k_numbers). The recall may also cover devices cleared under other submissions not named here.
Product description
V Series Patient Monitors; Mindray DS USA, Inc. Product Usage: The V Series Monitor is intended for intra hospital use under the direct supervision of a licensed healthcare practitioner. The indications for Use for the V Series include the monitoring of the following human physiological parameters: ECG waveform derived from 3, 5, 6 and 12 lead measurements; Heart Rate; Pulse Oximetry (SpO2); ST Segment Analysis; Arrhythmia Detection; Non Invasive Blood Pressure (NIBP); Invasive Blood Pressure (IBP); Cardiac Output (CO); Respiratory Gasses; Respiration Rate; and Temperature. The V Series Monitor has the capability of performing IV Drug and Hemodynamic Calculations and interfacing with network devices. The target populations are adult, pediatric and neonate with the exception of: Arrhythmia detection and ST Segment Analysis, for which the target populations are adult and pediatric only; IV Drug Calculations for which the target population is adult only; and Cardiac Output for which the target population is adult and pediatric only.
Reason for recall
Mindray has identified two software anomalies contained in the V Series Monitoring System. There have been no reports of injuries associated with these anomalies. These anomalies affect V Series Systems distributed between September 31, 2010 and January 9, 2012.