Recall Z-1892-2017— Zimmer Trabecular Metal Technology, Inc.

Class III · Terminated

Class III FDA medical device recall by Zimmer Trabecular Metal Technology, Inc., initiated 2016-07-07, terminated 2017-05-03. It names one FDA 510(k) clearance: K113561. Product: The TM Ardis Interbody System implant is a convex, straight TLIF or PLIF device for interbody fusion of the anterior column of the spine. TM Ardis is designed for fusing the adjacent bony surfaces and may be used to replace a disc at one or two contiguous levels in L2-S1. The superior and inferior surfaces of the device are textured to provide increased stability and convex to conform to the vertebral endplates. The device also has two slots on the posterior end to mate with the insertion instrument. The TM Ardis device is wholly comprised of Trabecular Metal Porous Tantalum. Surgical instrumentation for use with the proposed system will be fabricated from surgical grade stainless steel and other applicable materials.. Reason: This field action is being initiated following the firm's discovery of a procedural error in the approval of literature resulting in the undo release of certain content. Information was disseminated to distributors and sales representatives during the 2016 National Sales Meeting held February 17-21, 2016..

Recalling firm
Zimmer Trabecular Metal Technology, Inc.
Classification
Class III
Status
Terminated
Initiated
2016-07-07
Terminated
2017-05-03
Firm location
Parsippany, NJ, United States

510(k) clearances named in this recall

1 on FDA's record

K-numbers as listed on FDA's Recall Enterprise System record for this event (openFDA device/recall k_numbers). The recall may also cover devices cleared under other submissions not named here.

Product description

The TM Ardis Interbody System implant is a convex, straight TLIF or PLIF device for interbody fusion of the anterior column of the spine. TM Ardis is designed for fusing the adjacent bony surfaces and may be used to replace a disc at one or two contiguous levels in L2-S1. The superior and inferior surfaces of the device are textured to provide increased stability and convex to conform to the vertebral endplates. The device also has two slots on the posterior end to mate with the insertion instrument. The TM Ardis device is wholly comprised of Trabecular Metal Porous Tantalum. Surgical instrumentation for use with the proposed system will be fabricated from surgical grade stainless steel and other applicable materials.

Reason for recall

This field action is being initiated following the firm's discovery of a procedural error in the approval of literature resulting in the undo release of certain content. Information was disseminated to distributors and sales representatives during the 2016 National Sales Meeting held February 17-21, 2016.