Recall Z-1232-2018— Zimmer Biomet, Inc.
Class II · Terminated
Class II FDA medical device recall by Zimmer Biomet, Inc., initiated 2017-12-20, terminated 2020-04-22. It names 4 FDA 510(k) clearances: K111663, K042325, K013563 and 1 more. Product: ACE Trochanteric Nail System STER TROC NAIL 180X13X140 STER TROC NAIL 125 DEG X 13MM STER TROC NAIL 130 DEG X 13MM STER TROC NAIL 135 DEG X 13MM The Trochanteric Nail System is intended to treat stable and unstable proximal fractures of the femur including pertrochanteric fractures, intertrochanteric fractures, high subtrochanteric fractures and combinations of these fractures. The Trochanteric Long Nail System is additionally indicated to treat pertrochanteric fractures associated with shaft fractures, pathologic fractures in osteoporotic bone of the trochanteric and diaphyseal areas, long subtrochanteric fractures, ipsilateral femoral fractures, proximal or distal nonunions and malunions and revision procedures.. Reason: Zimmer Biomet is conducting a medical device recall for the ACE Trochanteric Nail (ATN) system after a Device Performance Review (DPR) failed clinical analysis for survivorship pursuant to the acceptance criteria for the DPR protocol for the ATN system..
- Recalling firm
- Zimmer Biomet, Inc.
- Classification
- Class II
- Status
- Terminated
- Initiated
- 2017-12-20
- Terminated
- 2020-04-22
- Firm location
- Warsaw, IN, United States
510(k) clearances named in this recall
4 on FDA's record- K111663 — TRAUMA INTERNAL FIXATION SYSTEMS
- K042325 — TROCHANTERIC NAIL SYSTEM
- K013563 — LONG TROCHANTERIC NAIL SYSTEM
- K010780 — TROCHANTERIC NAIL
K-numbers as listed on FDA's Recall Enterprise System record for this event (openFDA device/recall k_numbers). The recall may also cover devices cleared under other submissions not named here.
Product description
ACE Trochanteric Nail System STER TROC NAIL 180X13X140 STER TROC NAIL 125 DEG X 13MM STER TROC NAIL 130 DEG X 13MM STER TROC NAIL 135 DEG X 13MM The Trochanteric Nail System is intended to treat stable and unstable proximal fractures of the femur including pertrochanteric fractures, intertrochanteric fractures, high subtrochanteric fractures and combinations of these fractures. The Trochanteric Long Nail System is additionally indicated to treat pertrochanteric fractures associated with shaft fractures, pathologic fractures in osteoporotic bone of the trochanteric and diaphyseal areas, long subtrochanteric fractures, ipsilateral femoral fractures, proximal or distal nonunions and malunions and revision procedures.
Reason for recall
Zimmer Biomet is conducting a medical device recall for the ACE Trochanteric Nail (ATN) system after a Device Performance Review (DPR) failed clinical analysis for survivorship pursuant to the acceptance criteria for the DPR protocol for the ATN system.
Data sourced from openFDA. This site is unofficial and independent of the FDA.