Recall Z-0687-2017— MicroPort Orthopedics Inc.

Class III · Terminated

Class III FDA medical device recall by MicroPort Orthopedics Inc., initiated 2016-06-21, terminated 2017-07-01. It names one FDA 510(k) clearance: K100866. Product: Conserve Shells: REF 38021146, REF 38021148, REF 38021150, REF 38021152, REF 38021154, REF 38021156, REF 38021158, REF 38021160, REF 38021162, REF 38021164, REF 38023642, REF 38023646, REF 38023844, REF 38023848, REF 38024046, REF 38024050, REF 38024248, REF 38024252, REF 38024450, REF 38024454, REF 38024652, REF 38024656, REF 38024854, REF 38024858, REF 38025056, REF 38025060, REF 38025258, REF 38025262, REF 38025460, REF 38025464, REF 38025662, REF 38025664, REF 38025666, REF 38025668, REF 38123844, REF 38124046, REF 38124248, REF 38124450, REF 38125056, REF 38125662, REF 38HA3642, REF 38HA3844, REF 38HA4046, REF 38HA4248, REF 38HA4450, REF 38HA4652, REF 38HA4854, REF 38HA5056, REF 38HA5258, REF 38HA5460, REF 38HA5662, REF 38HA5664, REF 38HA5864, REF 38HA6066, REF 38SP3642, REF 38SP3844, REF 38SP4046, REF 38SP4248, REF 38SP4450, REF 38SP4652, REF 38SP4854, REF 38SP5056, REF 38SP5258, REF 38SP5460, REF 38SP5662, REF 38SP5664 For use with the conserve metal head. Reason: Revision rate trends from within the MicroPort Orthopedics Inc. database evaluated for the modular head Metal on Metal THA systems show an increasing overall trend from 2009 to present and it was found that there was a specific hazard/harm for suspected tissue reaction to metal debris over one percent for modular head CONSERVE(R) systems and DYNASTY(R) metal acetabular liner systems..

Recalling firm
MicroPort Orthopedics Inc.
Classification
Class III
Status
Terminated
Initiated
2016-06-21
Terminated
2017-07-01
Firm location
Arlington, TN, United States

510(k) clearances named in this recall

1 on FDA's record

K-numbers as listed on FDA's Recall Enterprise System record for this event (openFDA device/recall k_numbers). The recall may also cover devices cleared under other submissions not named here.

Product description

Conserve Shells: REF 38021146, REF 38021148, REF 38021150, REF 38021152, REF 38021154, REF 38021156, REF 38021158, REF 38021160, REF 38021162, REF 38021164, REF 38023642, REF 38023646, REF 38023844, REF 38023848, REF 38024046, REF 38024050, REF 38024248, REF 38024252, REF 38024450, REF 38024454, REF 38024652, REF 38024656, REF 38024854, REF 38024858, REF 38025056, REF 38025060, REF 38025258, REF 38025262, REF 38025460, REF 38025464, REF 38025662, REF 38025664, REF 38025666, REF 38025668, REF 38123844, REF 38124046, REF 38124248, REF 38124450, REF 38125056, REF 38125662, REF 38HA3642, REF 38HA3844, REF 38HA4046, REF 38HA4248, REF 38HA4450, REF 38HA4652, REF 38HA4854, REF 38HA5056, REF 38HA5258, REF 38HA5460, REF 38HA5662, REF 38HA5664, REF 38HA5864, REF 38HA6066, REF 38SP3642, REF 38SP3844, REF 38SP4046, REF 38SP4248, REF 38SP4450, REF 38SP4652, REF 38SP4854, REF 38SP5056, REF 38SP5258, REF 38SP5460, REF 38SP5662, REF 38SP5664 For use with the conserve metal head

Reason for recall

Revision rate trends from within the MicroPort Orthopedics Inc. database evaluated for the modular head Metal on Metal THA systems show an increasing overall trend from 2009 to present and it was found that there was a specific hazard/harm for suspected tissue reaction to metal debris over one percent for modular head CONSERVE(R) systems and DYNASTY(R) metal acetabular liner systems.

Data sourced from openFDA. This site is unofficial and independent of the FDA.