Recall Z-0500-2025— NuVasive Specialized Orthopedics, Inc.
Class II · Ongoing
Class II FDA medical device recall by NuVasive Specialized Orthopedics, Inc., initiated 2024-09-30. It names one FDA 510(k) clearance: K232267. Product: Precice Max REF: PM10.0-80B265 PRECICE MAX Antegrade Femur Piriformis Straight 10.0mm x 265mm PM10.0-80B280 PRECICE MAX Antegrade Femur Piriformis Straight 10.0mm x 280mm PM10.0-80B305 PRECICE MAX Antegrade Femur Piriformis Straight 10.0mm x 305mm PM10.0-80B335 PRECICE MAX Antegrade Femur Piriformis Straight 10.0mm x 335mm PM10.0-80B365 PRECICE MAX Antegrade Femur Piriformis Straight 10.0mm x 365mm PM10.0-80TJ265 PRECICE MAX Antegrade Tibia 10¿ Bend 3 Hole 10.0mm x 265mm PM10.0-80TJ280 PRECICE MAX Antegrade Tibia 10¿ Bend 3 Hole 10.0mm x 280mm PM10.0-80TJ305 PRECICE MAX Antegrade Tibia 10¿ Bend 3 Hole 10.0mm x 305mm PM11.5-80B265 PRECICE MAX Antegrade Femur Piriformis Straight 11.5mm x 265mm PM11.5-80B280 PRECICE MAX Antegrade Femur Piriformis Straight 11.5mm x 280mm PM11.5-80B305 PRECICE MAX Antegrade Femur Piriformis Straight 11.5mm x 305mm PM11.5-80B335 PRECICE MAX Antegrade Femur Piriformis Straight 11.5mm x 335mm PM11.5-80B365 PRECICE MAX Antegrade Femur Piriformis Straight 11.5mm x 365mm PM11.5-80TJ265 PRECICE MAX Antegrade Tibia 10¿ Bend 3 Hole 11.5mm x 265mm PM11.5-80TJ280 PRECICE MAX Antegrade Tibia 10¿ Bend 3 Hole 11.5mm x 280mm PM11.5-80TJ305 PRECICE MAX Antegrade Tibia 10¿ Bend 3 Hole 11.5mm x 305mm PM13.0-80B280 PRECICE MAX Antegrade Femur Piriformis Straight 13.0mm x 280mm PM13.0-80B305 PRECICE MAX Antegrade Femur Piriformis Straight 13.0mm x 305mm PM13.0-80B365 PRECICE MAX Antegrade Femur Piriformis Straight 13.0mm x 365mm The Precice Max Nail is intended to stabilize fractures, nonunions, and malunions of the femur, tibia, and humerus. In addition, the Precice Nail is intended to provide magnetically controlled lengthening of long bones and/or transporting of bone segments in the femur, tibia, and humerus.. Reason: Due to potential issues with design, manufacturing and documentation issues related to the validation of the affected products/devices..
- Recalling firm
- NuVasive Specialized Orthopedics, Inc.
- Classification
- Class II
- Status
- Ongoing
- Initiated
- 2024-09-30
- Firm location
- Aliso Viejo, CA, United States
510(k) clearances named in this recall
1 on FDA's recordK-numbers as listed on FDA's Recall Enterprise System record for this event (openFDA device/recall k_numbers). The recall may also cover devices cleared under other submissions not named here.
Product description
Precice Max REF: PM10.0-80B265 PRECICE MAX Antegrade Femur Piriformis Straight 10.0mm x 265mm PM10.0-80B280 PRECICE MAX Antegrade Femur Piriformis Straight 10.0mm x 280mm PM10.0-80B305 PRECICE MAX Antegrade Femur Piriformis Straight 10.0mm x 305mm PM10.0-80B335 PRECICE MAX Antegrade Femur Piriformis Straight 10.0mm x 335mm PM10.0-80B365 PRECICE MAX Antegrade Femur Piriformis Straight 10.0mm x 365mm PM10.0-80TJ265 PRECICE MAX Antegrade Tibia 10¿ Bend 3 Hole 10.0mm x 265mm PM10.0-80TJ280 PRECICE MAX Antegrade Tibia 10¿ Bend 3 Hole 10.0mm x 280mm PM10.0-80TJ305 PRECICE MAX Antegrade Tibia 10¿ Bend 3 Hole 10.0mm x 305mm PM11.5-80B265 PRECICE MAX Antegrade Femur Piriformis Straight 11.5mm x 265mm PM11.5-80B280 PRECICE MAX Antegrade Femur Piriformis Straight 11.5mm x 280mm PM11.5-80B305 PRECICE MAX Antegrade Femur Piriformis Straight 11.5mm x 305mm PM11.5-80B335 PRECICE MAX Antegrade Femur Piriformis Straight 11.5mm x 335mm PM11.5-80B365 PRECICE MAX Antegrade Femur Piriformis Straight 11.5mm x 365mm PM11.5-80TJ265 PRECICE MAX Antegrade Tibia 10¿ Bend 3 Hole 11.5mm x 265mm PM11.5-80TJ280 PRECICE MAX Antegrade Tibia 10¿ Bend 3 Hole 11.5mm x 280mm PM11.5-80TJ305 PRECICE MAX Antegrade Tibia 10¿ Bend 3 Hole 11.5mm x 305mm PM13.0-80B280 PRECICE MAX Antegrade Femur Piriformis Straight 13.0mm x 280mm PM13.0-80B305 PRECICE MAX Antegrade Femur Piriformis Straight 13.0mm x 305mm PM13.0-80B365 PRECICE MAX Antegrade Femur Piriformis Straight 13.0mm x 365mm The Precice Max Nail is intended to stabilize fractures, nonunions, and malunions of the femur, tibia, and humerus. In addition, the Precice Nail is intended to provide magnetically controlled lengthening of long bones and/or transporting of bone segments in the femur, tibia, and humerus.
Reason for recall
Due to potential issues with design, manufacturing and documentation issues related to the validation of the affected products/devices.
Data sourced from openFDA. This site is unofficial and independent of the FDA.