Recall Z-0483-2016— Cardica, Inc.
Class II · Terminated
Class II FDA medical device recall by Cardica, Inc., initiated 2015-11-06, terminated 2016-02-12. It names 2 FDA 510(k) clearances: K140118, K140170. Product: MicroCutter Xchange 30 Blue Curved Tip Cartridge. Model Number: FG-025321; The MicroCutter XCHANGE 30 Blue Cartridge and MicroCutter XCHANGE 30 Blue Curved Tip Cartridge contain 316L stainless steel staples. The cartridges are used with the MicroCutter XCHANGE 30 Stapler, which is a single patient device. When the MicroCutter XCHANGE 30 Stapler is loaded with a MicroCutter XCHANGE 30 Cartridge, two double rows of 316L stainless steel staples are delivered while simultaneously transecting tissue between the two, double staple rows. The MicroCutter XCHANGE 30 Stapler and MicroCutter XCHANGE 30 Cartridge are designed for introduction and use through a 5mm trocar cannula or larger. The staple line length is 30 mm long. The Stapler can be loaded, fired, and reloaded with the MicroCutter XCHANGE 30 Cartridge for up to the number deployments indicated on package label in a single surgical procedure. The Stapler can fire different sized staples, with the size of the staple indicated by the color of the MicroCutter XCHANGE Cartridges. Intended for use in multiple open or minimally invasive surgical procedures for the transaction, resection, and /or creation of anastomoses in small and large intestine as well as the transection of the appendix.. Reason: Cardica, Inc. has received reports that use of the Blue Cartridges with the MicroCutter XCHANGE 30 Stapler was associated with incomplete firing of staples, potentially resulting in an incomplete transection or anastomosis of tissue during the surgical procedure..
- Recalling firm
- Cardica, Inc.
- Classification
- Class II
- Status
- Terminated
- Initiated
- 2015-11-06
- Terminated
- 2016-02-12
- Firm location
- Redwood City, CA, United States
510(k) clearances named in this recall
2 on FDA's record- K140118 — MICROCUTTER XCHANGE 30 STAPLER, MICROCUTTER XCHANGE 30 BLUE CARTRIDGE
- K140170 — MICROCUTTER XCHANGE 30 STAPLER, MICROCUTTER XCHANGE 30 WHITE CARTRIDGE
K-numbers as listed on FDA's Recall Enterprise System record for this event (openFDA device/recall k_numbers). The recall may also cover devices cleared under other submissions not named here.
Product description
MicroCutter Xchange 30 Blue Curved Tip Cartridge. Model Number: FG-025321; The MicroCutter XCHANGE 30 Blue Cartridge and MicroCutter XCHANGE 30 Blue Curved Tip Cartridge contain 316L stainless steel staples. The cartridges are used with the MicroCutter XCHANGE 30 Stapler, which is a single patient device. When the MicroCutter XCHANGE 30 Stapler is loaded with a MicroCutter XCHANGE 30 Cartridge, two double rows of 316L stainless steel staples are delivered while simultaneously transecting tissue between the two, double staple rows. The MicroCutter XCHANGE 30 Stapler and MicroCutter XCHANGE 30 Cartridge are designed for introduction and use through a 5mm trocar cannula or larger. The staple line length is 30 mm long. The Stapler can be loaded, fired, and reloaded with the MicroCutter XCHANGE 30 Cartridge for up to the number deployments indicated on package label in a single surgical procedure. The Stapler can fire different sized staples, with the size of the staple indicated by the color of the MicroCutter XCHANGE Cartridges. Intended for use in multiple open or minimally invasive surgical procedures for the transaction, resection, and /or creation of anastomoses in small and large intestine as well as the transection of the appendix.
Reason for recall
Cardica, Inc. has received reports that use of the Blue Cartridges with the MicroCutter XCHANGE 30 Stapler was associated with incomplete firing of staples, potentially resulting in an incomplete transection or anastomosis of tissue during the surgical procedure.