Recall Z-0217-2015— Edwards Lifesciences, LLC
Class II · Terminated
Class II FDA medical device recall by Edwards Lifesciences, LLC, initiated 2014-10-08, terminated 2016-12-15. It names one FDA 510(k) clearance: K113411. Product: Edwards Lifesciences Vent Catheters, . Packaged sterile and non-pyrogenic in a sealed, peel-type pouch. Model Numbers: E061, E060, PE062, EM012 Atrial Vent Catheters are intended for venting the left heart during short-term ( d 6 hrs) cardiopulmonary bypass. Avoid direct ventriculotomy with entry into the left atrium across the mitral valve and into the left ventricle. Left Ventricular Vent Catheters are intended for venting the left ventricle during short-term ( 6 hrs) cardiopulmonary bypass. Entrance is made into the left ventricle. Extracorporeal circuit components with a Duraflo coating are intended for use in cardiopulmonary surgery when a heparin coated blood path is desired. Vent Catheters may be used in pediatric or adult populations based on individual patient anatomy.. Reason: Edwards Lifesciences is conducting a field action on the Vent Catheters due to the potential for disruption of the white plastic coating on the stylet..
- Recalling firm
- Edwards Lifesciences, LLC
- Classification
- Class II
- Status
- Terminated
- Initiated
- 2014-10-08
- Terminated
- 2016-12-15
- Firm location
- Draper, UT, United States
510(k) clearances named in this recall
1 on FDA's recordK-numbers as listed on FDA's Recall Enterprise System record for this event (openFDA device/recall k_numbers). The recall may also cover devices cleared under other submissions not named here.
Product description
Edwards Lifesciences Vent Catheters, . Packaged sterile and non-pyrogenic in a sealed, peel-type pouch. Model Numbers: E061, E060, PE062, EM012 Atrial Vent Catheters are intended for venting the left heart during short-term ( d 6 hrs) cardiopulmonary bypass. Avoid direct ventriculotomy with entry into the left atrium across the mitral valve and into the left ventricle. Left Ventricular Vent Catheters are intended for venting the left ventricle during short-term ( 6 hrs) cardiopulmonary bypass. Entrance is made into the left ventricle. Extracorporeal circuit components with a Duraflo coating are intended for use in cardiopulmonary surgery when a heparin coated blood path is desired. Vent Catheters may be used in pediatric or adult populations based on individual patient anatomy.
Reason for recall
Edwards Lifesciences is conducting a field action on the Vent Catheters due to the potential for disruption of the white plastic coating on the stylet.