Recall Z-0111-2017— Zimmer Biomet, Inc.

Class II · Terminated

Class II FDA medical device recall by Zimmer Biomet, Inc., initiated 2016-08-09, terminated 2017-05-17. It names one FDA 510(k) clearance: K023546. Product: Vanguard Distal Femoral Augment 75 X 5 RL/LM Product Usage:  Painful and disabled knee joint resulting from osteoarthritis, rheumatoid arthritis, traumatic arthritis where one or more compartments are involved.  Correction of varus, valgus, or posttraumatic deformity.  Correction or revision of unsuccessful osteotomy, arthrodesis, or failure of previous joint replacement procedure.  The device is a single use implant intended for implantation with bone cement.. Reason: Contents of the package do not match the product labeling. Product is labeled: Vanguard Distal Femoral Augment 75 X 5 RL/LM Carton contains: Vanguard Distal Femoral Augment 75 X 5 LL/RM Risks: Adverse health outcomes that could occur as a result of this event are a delay less than 30 minutes and a different size augment being used to complete the procedure. As the augment will not assemble with femoral component due to its shape, it would be easily identified during surgery..

Recalling firm
Zimmer Biomet, Inc.
Classification
Class II
Status
Terminated
Initiated
2016-08-09
Terminated
2017-05-17
Firm location
Warsaw, IN, United States

510(k) clearances named in this recall

1 on FDA's record

K-numbers as listed on FDA's Recall Enterprise System record for this event (openFDA device/recall k_numbers). The recall may also cover devices cleared under other submissions not named here.

Product description

Vanguard Distal Femoral Augment 75 X 5 RL/LM Product Usage:  Painful and disabled knee joint resulting from osteoarthritis, rheumatoid arthritis, traumatic arthritis where one or more compartments are involved.  Correction of varus, valgus, or posttraumatic deformity.  Correction or revision of unsuccessful osteotomy, arthrodesis, or failure of previous joint replacement procedure.  The device is a single use implant intended for implantation with bone cement.

Reason for recall

Contents of the package do not match the product labeling. Product is labeled: Vanguard Distal Femoral Augment 75 X 5 RL/LM Carton contains: Vanguard Distal Femoral Augment 75 X 5 LL/RM Risks: Adverse health outcomes that could occur as a result of this event are a delay less than 30 minutes and a different size augment being used to complete the procedure. As the augment will not assemble with femoral component due to its shape, it would be easily identified during surgery.