BD Nexiva Closed IV Catheter System— 510(k) K183399
Substantially EquivalentBecton Dickinson Infusion Therapy Systems, Inc.
FDA 510(k) clearance K183399 for BD Nexiva Closed IV Catheter System, Substantially Equivalent on 2019-03-20. Applicant: Becton Dickinson Infusion Therapy Systems, Inc.. Device class: 2.
Clearance details
- Applicant
- Becton Dickinson Infusion Therapy Systems, Inc.
- Product code
- Code FOZ
- Device class
- Class 2
- Regulation
- 21 CFR 880.5200
- Advisory panel
- General Hospital
- Date received
- Decision date
- Decision
- Substantially Equivalent
- Clearance type
- Traditional
- Location
- Sandy, UT, US
Recent devices under product code FOZ
view allMore clearances from Becton Dickinson Infusion Therapy Systems, Inc.
view all- K252137 — BD Insyte IV Catheter
- K251422 — BD Saf-T-Intima Subcutaneous Catheter System
- K243403 — BD Nexiva Closed IV Catheter System
- K251155 — BD Cathena Safety IV Catheter
- K251654 — BD Insyte Autoguard Shielded IV Catheter, BD Insyte Autoguard BC Shielded IV Catheter and BD Insyte Autoguard BC Pro Shielded IV Catheter
Adverse events under product code FOZ
product code FOZ- Death
- 38
- Injury
- 2,290
- Malfunction
- 25,858
- Other
- 11
- Total
- 28,197
Source: openFDA MAUDE database, through . Counts aggregate all devices under this product code, not just this specific clearance. Reports are submissions to FDA, not validated events. Search MAUDE directly →
Recalls naming K183399
K-number listed on FDA's recall record- Z-0174-2023 — BD Nexiva Closed IV Catheter System - Single Port REF 383516 20 GA X1.0o in (1.1 x 25 mm) 61 mL/min (3660 mL/hr)
- Z-0306-2022 — BD Nexiva, 20 GA 1.00 IN (1.1 X 25 mm), 3660 ml/hr. 61ml/min; Closed IV Catheter System- Dual port -61 mL/min (3660 mL/hr)-0.5mL, REF 383536; BD Q-Style Luer Access Split Septum BD Vialon Material; BD Instaflash Needle Technology; Rx Only, Sterile EO. BD Nexiva closed IV catheter systems are over-the-needle, intravascular catheters. These devices have a radiopaque BD Vialon" catheter, needle, needle shield, septum, stabilization platform, integrated extension tubing, clamp, dual port adapter, vent plug and pre-attached BD Q-Syte Luer Access Split Septum. The needle and catheter are protected by a needle cover. A BD Q-Syte device or an end cap with protective cover is provided in the unit package. The closed system is designed to keep blood contained within the device throughout the insertion process. The septum is designed to wipe visible blood from the needle surface as the needle is withdrawn from the catheter, further reducing the risk of blood exposure. The needle tip is passively protected when the needle is removed, reducing the risk of accidental needlestick injury. These devices have BD Instaflash" Needle Technology, allowing for immediate visualization of blood along the catheter. Continuous blood return is seen in the extension tubing. The vent plug prevents blood leakage from the extension tubing during insertion. Both the stabilization platform and dual port adapter are color coded to indicate catheter gauge size (24GA (0.7 mm)=Yellow, 22GA (0.9 mm)=Blue, 20GA (1.1 mm)=Pink, 18GA (1.3 mm)=Green). BD Nexiva closed IV catheter systems are intended to be inserted into a patient s vascular system for short term use to sample blood, monitor blood pressure, or administer fluids. These catheters may be used for any patient population with consideration given to adequacy of vascular anatomy, procedure being performed, fluids being infused, and duration of therapy. The 22-18GA (0.9-1.3 mm) devices are suitable for use with power injectors set to a maximum pressure of 300 psi (2068 kPa) when access ports not suitable for use with power injectors are removed.
- Z-0125-2021 — BD Nexiva Closed IV Catheter System Dual Port (20 GA 1.75 IN) Catalog (Ref) No. 383538 BD Nexiva closed IV catheter systems are intended to be inserted into a patient s vascular system for short term use to sample blood, monitor blood pressure, or administer fluids.
Matched by K-number from FDA's Recall Enterprise System record (openFDA device/recallk_numbers) — these recalls explicitly list K183399.