MicroPlex Coil System (MCS), Hydrocoil Embolic System (HES)— 510(k) K153594
Substantially EquivalentMicroVention, Inc.
FDA 510(k) clearance K153594 for MicroPlex Coil System (MCS), Hydrocoil Embolic System (HES), Substantially Equivalent on 2016-01-22. Applicant: MicroVention, Inc.. Device class: 2.
Clearance details
- Applicant
- MicroVention, Inc.
- Product code
- Code HCG
- Device class
- Class 2
- Regulation
- 21 CFR 882.5950
- Advisory panel
- Neurology
- Date received
- Decision date
- Decision
- Substantially Equivalent
- Clearance type
- Special
- Location
- Tistin, CA, US
Recent devices under product code HCG
view allMore clearances from MicroVention, Inc.
view all- K232542 — Wedge XL Delivery Catheter
- K230775 — SOFIA EX Intracranial Support Catheter
- K222694 — EmPro EPS (EP4514C-190, EP6514C-190); Nanoparasol EPS (PNP4514C-190,PNP6514C-190)
- K222115 — ISAAC Neurovascular Navigation Catheter
- K223050 — AZUR HydroPack 18 (45-880005; 45-880010; 45-880020; 45-880035; 45-880050; 45-880060)
Adverse events under product code HCG
product code HCG- Death
- 50
- Injury
- 801
- Malfunction
- 5,625
- Total
- 6,476
Source: openFDA MAUDE database, through . Counts aggregate all devices under this product code, not just this specific clearance. Reports are submissions to FDA, not validated events. Search MAUDE directly →
Recalls naming K153594
K-number listed on FDA's recall record- Z-1392-2020 — MicroVention Terumo HydroSoft 10, HydroCoil Embolic System, Endovascular Embolization Coil, Helical, Sterile, Rx, REF numbers 100101H2HS-V; 100102H2HS-V, 100103H2HS-V, 100104H2HS-V, 100151H2HS-V; 100152H2HS-V; 100153H2HS-V; 100154H2HS-V; 100201H2HS-V; 100202H2HS-V; 100203H2HS-V; 100204H2HS-V; 100206H2HS-V, 100208H2HS-V, 100254H2HS-V, 100256H2HS-V, 100304H2HS-V; 100306H2HS-V; 100308H2HS-V; 100310H2HS-V; 100404H2HS-V; 100406H2HS-V, 100408H2HS-V, 100410H2HS-V, 100506H2HS-V, 100508H2HS-V; 100510H2HS-V, 100515H2HS-V, 100520H2HS-V, 100620H2HS-V, and MV-00208HHSA - Product Usage: The HES is also intended for vascular occlusion of blood vessels within the neurovascular system to permanently obstruct blood flow to an aneurysm or other vascular malformation and for arterial and venous embolizations in the peripheral vasculature. The firm name on the label is MicroVention, Inc., Tustin, CA.
- Z-1393-2020 — MicroVention Terumo Microplex 10, Platinum Coil System, Endovascular Embolization Coil, HyperSoft 3D, Sterile, Rx, REF numbers 100102HS3D-V, 100103HS3D-V, 100152HS3D-V, 100153HS3D-V, 100154HS3D-V, 100202HS3D-V, 100203HS3D-V, 100204HS3D-V, 100206HS3D-V, 100208HS3D-V, 100254HS3D-V, 100256HS3D-V, 100304HS3D-V, 100306HS3D-V, 100310HS3D-V, 100355HS3D-V, 100358HS3D-V, 100406HS3D-V, 100408HS3D-V, 100412HS3D-V, 100415HS3D-V, 100510HS3D-V, 100515HS3D-V; MV-00102HTDA, MV-00103HTDA, MV-00204HTDA,MV-00304HTDA, MV-00306HTDA, MV-00406HTDA, MV-00408HTDA, MV-00510HTDA, MV-01502HTDA, MV-01503HTDA, MV-01504HTDA; MV-02504HTDA, MV-02506HTDA, MV-03505HTDA, and MV-03508HTDA. Product Usage: The MCS is also intended for vascular occlusion of blood vessels within the neurovascular system to permanently obstruct blood flow to an aneurysm or other vascular malformation and for arterial and venous embolizations in the peripheral vasculature. The firm name on the label is MicroVention, Inc., Tustin, CA.
- Z-1394-2020 — MicroVention Terumo Microplex 10, Platinum Coil System, Endovascular Embolization Coil, Helical 10 Regular, Sterile, Rx, REF numbers 100515HC-R-V, 100515HCSR-R-V, 100520HC-R-V, 100520HCSR-R-V, 100620HC-R-V, 100620HCSR-R-V, 100730HC-R-V, 100730HCSR-R-V, 100830HC-R-V, 100930HC-R-V, 100930HCSR-R-V, 101030HC-R-V, and 101030HCSR-R-V. Product Usage: The MCS is also intended for vascular occlusion of blood vessels within the neurovascular system to permanently obstruct blood flow to an aneurysm or other vascular malformation and for arterial and venous embolizations in the peripheral vasculature. The firm name on the label is MicroVention, Inc., Tustin, CA.
- Z-1395-2020 — MicroVention Terumo Microplex 10, Platinum Coil System, Endovascular Embolization Coil, Helical 10 Soft, Sterile, Rx, REF numbers 100206HCSR-S-V, 100208HC-S-V, 100208HCSR-S-V, 100306HCSR-S-V, 100308HCSR-S-V, 100310HC-S-V, 100310HCSR-S-V, 100410HC-S-V, 100410HCSR-S-V, Product Usage: The MCS is also intended for vascular occlusion of blood vessels within the neurovascular system to permanently obstruct blood flow to an aneurysm or other vascular malformation and for arterial and venous embolizations in the peripheral vasculature. The firm name on the label is MicroVention, Inc., Tustin, CA.
- Z-1396-2020 — MicroVention Terumo Microplex 18, Platinum Coil System, Endovascular Embolization Coil, Helical 18 Regular, Sterile, Rx, REF numbers 180520HC-R-V and 181230HC-R-V. Product Usage: The MCS is also intended for vascular occlusion of blood vessels within the neurovascular system to permanently obstruct blood flow to an aneurysm or other vascular malformation and for arterial and venous embolizations in the peripheral vasculature. The firm name on the label is MicroVention, Inc., Tustin, CA.
- Z-1397-2020 — MicroVention Terumo Microplex 18, Platinum Coil System, Endovascular Embolization Coil, Helical 18 Soft, Sterile, Rx, REF numbers 180204HC-S-V, 180208HC-S-V, 180308HC-S-V, 180410HC-S-V, and 180512HC-S-V. Product Usage: The MCS is also intended for vascular occlusion of blood vessels within the neurovascular system to permanently obstruct blood flow to an aneurysm or other vascular malformation and for arterial and venous embolizations in the peripheral vasculature.
- Z-1398-2020 — MicroVention Terumo Microplex 10, Platinum Coil System, Endovascular Embolization Coil, Cosmos 10, Sterile, Rx, REF numbers 100202CSSR-V, 100254CSSR-V, 100306CSSR-V, 100408CSSR-V, 100412CSSR-V, 100515CSSR-V, 100522CSSR-V, 100618CSSR-V, 100626CSSR-V, 100722CSSR-V, 100731CSSR-V, 100825CSSR-V, 100837CSSR-V, 100933CSSR-V, and 101036CSSR-V. Product Usage: The MCS is also intended for vascular occlusion of blood vessels within the neurovascular system to permanently obstruct blood flow to an aneurysm or other vascular malformation and for arterial and venous embolizations in the peripheral vasculature. The firm name on the label is MicroVention, Inc., Tustin, CA.
- Z-1399-2020 — MicroVention Terumo Microplex 18, Platinum Embolization Coil, Cosmos 18, Sterile, Rx, REF numbers 180619CS-V, 180723CS-V, 180827CS-V, 180931CS-V, 181036CS-V, 181139CS-V, 181243CS-V, 181347CS-V, 181451CS-V, 181652CS-V, 181859CS-V, 182065CS-V, 182263CS-V, and 182468CS-V; Product Usage: The MCS is also intended for vascular occlusion of blood vessels within the neurovascular system to permanently obstruct blood flow to an aneurysm or other vascular malformation and for arterial and venous embolizations in the peripheral vasculature. The firm name on the label is MicroVention, Inc., Tustin, CA.
- Z-1400-2020 — MicroVention Terumo Microplex 10, Platinum Coil System, Endovascular Embolization Coil, Complex 10, Sterile, Rx, REF numbers 100204CC-V, 100307CC-V, 100410CC-V, 100512CC-V, 100615CC-V, 100718CC-V, 100820CC-V, 100924CC-V, and 101026CC-V. Product Usage: The MCS is also intended for vascular occlusion of blood vessels within the neurovascular system to permanently obstruct blood flow to an aneurysm or other vascular malformation and for arterial and venous embolizations in the peripheral vasculature. The firm name on the label is MicroVention, Inc., Tustin, CA.
- Z-1401-2020 — MicroVention Terumo Microplex 18, Platinum Coil System, Endovascular Embolization Coil, Complex 18, Sterile, Rx, REF numbers 180512CC-V, 180820CC-V, 181026CC-V, 181434CC-V, and 182050CC-V. Product Usage: The MCS is also intended for vascular occlusion of blood vessels within the neurovascular system to permanently obstruct blood flow to an aneurysm or other vascular malformation and for arterial and venous embolizations in the peripheral vasculature. The firm name on the label is MicroVention, Inc., Tustin, CA.
- Z-1402-2020 — MicroVention Terumo HydroFrame 10, HydroCoil Embolic System, Endovascular Embolization Coil, Sterile, Rx, REF numbers 100306HFRM-V, 100405HFRM-V, 100408HFRM-V, 100410HFRM-V, 100412HFRM-V, 100415HFRM-V, 100510HFRM-V, 100515HFRM-V, 100519HFRM-V, 100612HFRM-V, 100619HFRM-V, 100623HFRM-V, 100715HFRM-V, 100728HFRM-V, 100817HFRM-V, 100833HFRM-V, 100931HFRM-V; 101036HFRM-V, MV-00408HHFA, MV-00510HHFA, MV-00515HHFA, and MV-00619HHFA. Product Usage: The HES is also intended for vascular occlusion of blood vessels within the neurovascular system to permanently obstruct blood flow to an aneurysm or other vascular malformation and for arterial and venous embolizations in the peripheral vasculature.
- Z-1403-2020 — MicroVention Terumo HydroFrame 18, HydroCoil Embolic System, Endovascular Embolization Coil, Sterile, Rx, REF numbers 180723HFRM-V, 180931HFRM-V, 181644HFRM-V, MV-80619HHFA, MV80827HHFA, MV-80931HHFA, and MV-81036HHFA. Product Usage: The HES is also intended for vascular occlusion of blood vessels within the neurovascular system to permanently obstruct blood flow to an aneurysm or other vascular malformation and for arterial and venous embolizations in the peripheral vasculature. The firm name on the label is MicroVention, Inc., Tustin, CA.
- Z-1404-2020 — MicroVention Terumo Microplex 10, Platinum Coil System, Endovascular Embolization Coil, Compass 10, Sterile, Rx, REF numbers 100203CMSR-V, 100408CMSR-V, 100412CMSR-V, 100510CMSR-V, 100516CMSR-V, 100612CMSR-V, 100618CMSR-V, and 100721CMSR-V. Product Usage: The MCS is also intended for vascular occlusion of blood vessels within the neurovascular system to permanently obstruct blood flow to an aneurysm or other vascular malformation and for arterial and venous embolizations in the peripheral vasculature. The firm name on the label is MicroVention, Inc., Tustin, CA.
- Z-1405-2020 — MicroVention Terumo HydroSoft 10, HydroCoil Embolic System, Endovascular Embolization Coil, HydroSoft 3D, Sterile, Rx, REF numbers 100102HFRM-V, 100152HFRM-V, 100153HFRM-V, 100154HFRM-V, 100202HFRM-V, 100206HFRM-V, 100208HFRM-V, 100254HFRM-V, 100256HFRM-V, 100308HFRM-V, MV-00202HHTA, MV-00203HHTA, MV-00204HHTA, MV-00206HHTA, MV-00208HHTA, MV-00304HHTA, MV-00306HHTA, MV-00308HHTA, MV-00310HHTA, MV-00408HHTA, MV-00412HHTA, MV-00510HHTA, MV-00515HHTA, MV-00612HHTA, MV-00619HHTA, MV-00715HHTA, MV-00728HHTA, MV-00817HHTA, MV-00833HHTA, MV-01502HHTA, MV-01503HHTA, MV-01504HHTA, MV-02504HHTA, MV-02506HHTA, and MV-02508HHTA. Product Usage: The HES is also intended for vascular occlusion of blood vessels within the neurovascular system to permanently obstruct blood flow to an aneurysm or other vascular malformation and for arterial and venous embolizations in the peripheral vasculature. The firm name on the label is MicroVention, Inc., Tustin, CA.
- Z-1406-2020 — MicroVention Terumo Microplex, Platinum Coil System, Endovascular Embolization Coil, VFC, Sterile, Rx, REF numbers MV-00306VFC, MV-00315VFC, MV-00310VFC, MV-00630VFC, VFC010303-V, VFC030606-V, VFC030610-V, VFC030615-V, VFC061020-V, VFC061030-V, VFC101530-V, VFC101540-V, VFC152040-V, and VFC152060-V. Product Usage: . The MCS is also intended for vascular occlusion of blood vessels within the neurovascular system to permanently obstruct blood flow to an aneurysm or other vascular malformation and for arterial and venous embolizations in the peripheral vasculature. The firm name on the label is MicroVention, Inc., Tustin, CA.
- Z-1407-2020 — MicroVention Terumo Microplex 10, Platinum Coil System, Endovascular Embolization Coil, HyperSoft Helical, Sterile, Rx, REF numbers 100101HS-V, 100102HS-V, 100103HS-V, 100104HS-V, 100151HS-V, 100152HS-V, 100153HS-V, 100154HS-V, 100201HS-V, 100202HS-V, 100203HS-V, 100204HS-V, 100206HS-V, 100254HS-V, 100256HS-V, 100304HS-V, 100306HS-V, 100308HS-V, 100406HS-V, 100408HS-V, and 100508HS-V. Product Usage: The MCS is also intended for vascular occlusion of blood vessels within the neurovascular system to permanently obstruct blood flow to an aneurysm or other vascular malformation and for arterial and venous embolizations in the peripheral vasculature. The firm name on the label is MicroVention, Inc., Tustin, CA.
Matched by K-number from FDA's Recall Enterprise System record (openFDA device/recallk_numbers) — these recalls explicitly list K153594.