TRIATHLON KNEE SYSTEM POSTERIOR STABILIZED COMPONENTS— 510(k) K141056
Substantially EquivalentStryker Orthopaedics
FDA 510(k) clearance K141056 for TRIATHLON KNEE SYSTEM POSTERIOR STABILIZED COMPONENTS, Substantially Equivalent on 2014-08-05. Applicant: Stryker Orthopaedics. Device class: 2.
Clearance details
- Applicant
- Stryker Orthopaedics
- Product code
- Code MBH
- Device class
- Class 2
- Regulation
- 21 CFR 888.3565
- Advisory panel
- Orthopedic
- Date received
- Decision date
- Decision
- Substantially Equivalent
- Clearance type
- Traditional
- Location
- Mahwah, NJ, US
Recent devices under product code MBH
view all- K253728 — EVOLUTION® AM BIOFOAM® Tibial System
- K251840 — Zimmer® Persona® Personalized Knee System
- K253189 — Persona the Personalized Knee System (Persona Porous Plasma Spray PPS Femurs)
- K253328 — GMK 3D Metal Tibial Tray Extension
- K253637 — Triathlon® Total Knee System - Triathlon® X3® Medial Stabilized Tibial Bearing Insert
More clearances from Stryker Orthopaedics
view allAdverse events under product code MBH
product code MBH- Injury
- 6,545
- Malfunction
- 2,023
- Total
- 8,568
Source: openFDA MAUDE database, through . Counts aggregate all devices under this product code, not just this specific clearance. Reports are submissions to FDA, not validated events. Search MAUDE directly →
Recalls naming K141056
K-number listed on FDA's recall record- Z-0023-2025 — Triathlon Universal TS Baseplate Size 2 - A single use sterile implantable device intended for cemented applications during primary and revision Total Knee Arthroplasty (TKA) when the Triathlon Knee System is selected for use. Catalog Number: 5521-B-200
- Z-2329-2021 — Triathlon Prim CEM FXD BPLT 7, Catalog No. 5520B700
- Z-1186-2021 — Prosthesis, knee, patello/femorotibial, semi-constrained, uncemented, porous, coated, polymer/metal/polymer.
- Z-2757-2019 — TRIATHLON FEMORAL DISTAL AUGMENT 10MM - SIZE 2 LEFT Catalog # 5541-A-201 - Product Usage: Triathlon Femoral Distal Augments are used with Triathlon TS Femoral Components during revision Total Knee Arthroplasty (TKA) and with Triathlon Primary PS Femoral Components during TKA to address distal femoral defects. (See attached IFU (IFU_Triathlon Total Knee_QIN 4376 Rev AB).
- Z-2758-2019 — TRIATHLON FEMORAL DISTAL AUGMENT 10MM - SIZE 2 RIGHT Catalog # 5541-A-202 - Product Usage: Triathlon Femoral Distal Augments are used with Triathlon TS Femoral Components during revision Total Knee Arthroplasty (TKA) and with Triathlon Primary PS Femoral Components during TKA to address distal femoral defects. (See attached IFU (IFU_Triathlon Total Knee_QIN 4376 Rev AB).
- Z-2759-2019 — TRIATHLON FEMORAL DISTAL AUGMENT 15MM - SIZE 2 LEFTTriathlon Femoral Distal Augments are used with Triathlon TS Femoral Components during revision Total Knee Arthroplasty (TKA) and with Triathlon Primary PS Femoral Components during TKA to address distal femoral defects. (See attached IFU (IFU_Triathlon Total Knee_QIN 4376 Rev AB) Catalog # 5542-A-201 - Product Usage:
- Z-2760-2019 — TRIATHLON FEMORAL DISTAL AUGMENT 15MM - SIZE 2 RIGHT Catalog # 5542-A-202 - Product Usage: Triathlon Femoral Distal Augments are used with Triathlon TS Femoral Components during revision Total Knee Arthroplasty (TKA) and with Triathlon Primary PS Femoral Components during TKA to address distal femoral defects. (See attached IFU (IFU_Triathlon Total Knee_QIN 4376 Rev AB).
- Z-1462-2018 — Triathlon Revision Knee Catalog #5545-A-301 and Catalog #5546-A-601 The knee system devices are sterile, single-use devices intended for us in revision total knee arthroplasty to alleviate pain and restore function.
- Z-1512-2018 — Knee Prosthesis, Sterile, Single-Use devices Product Usage: The knee system devices are intended for use in revision total knee arthroplasty to alleviate pain and restore function
- Z-2360-2015 — Triathlon PS X3 Tibial Insert; No. 3 Triathlon TS Plus Tibial Insert X3 Poly 19 mm Product Usage: The Triathlon PS X3 (posterior stabilized), cat no 5532-G-xxx and X3 TS (total stabilizing) Plus, cat. no. 5537-G-XXX, Tibial Inserts are used in TKA surgeries. During surgery, the tibial insert is locked into the tibial baseplate where it serves as the bearing component for the articulating surface of a corresponding Triathlon femoral component.