TOMOTHERAPY TREATMENT SYSTEM— 510(k) K121934
Substantially EquivalentAccuray Incorporated
FDA 510(k) clearance K121934 for TOMOTHERAPY TREATMENT SYSTEM, Substantially Equivalent on 2012-08-29. Applicant: Accuray Incorporated. Device class: 2.
Clearance details
- Applicant
- Accuray Incorporated
- Product code
- Code IYE
- Device class
- Class 2
- Regulation
- 21 CFR 892.5050
- Advisory panel
- Radiology
- Date received
- Decision date
- Decision
- Substantially Equivalent
- Clearance type
- Traditional
- Location
- Madison, WI, US
Recent devices under product code IYE
view allMore clearances from Accuray Incorporated
view all- K223159 — Radixact Treatment Delivery System
- K212794 — Accuray Precision Treatment Planning System
- K202412 — ClearRT Helical kVCT for the Radixact Treatment Delivery System
- K182687 — Motion Tracking and Compensation Feature for the Radixact Treatment Delivery System
- K171837 — TomoTherapy Treatment Delivery System with iDMS
Adverse events under product code IYE
product code IYE- Malfunction
- 455
- Other
- 3
- Total
- 458
Source: openFDA MAUDE database, through . Counts aggregate all devices under this product code, not just this specific clearance. Reports are submissions to FDA, not validated events. Search MAUDE directly →
Recalls naming K121934
K-number listed on FDA's recall record- Z-0784-2021 — TomoTherapy Treatment System - Product Usage: used as an integrated system for the planning and precise delivery of radiation therapy, stereotactic radiotherapy, or stereotactic radiosurgery to tumors or other targeted tissues while minimizing the delivery of radiation to vital healthy tissue.
- Z-0286-2018 — Hi-Art(R) System, Model Number H-000-0003 Product Usage: The TomoTherapy treatment system is intended to be used as an integrated system for t he planning and precise delivery of radiation therapy, stereotactic radiotherapy, or stereotactic radiosurgery to tumors or other targeted tissues while minimizing the delivery of radiation to vital healthy tissues. The megavoltage x-ray radiation is delivered in a rotational, non-rotational, modulated (IMRT), or non- modulated (non-IMRT/3 dimensional conformal) format in accordance with the physicians prescribed and approved plan.
- Z-0287-2018 — TomoHD(R) System, Model Number 1018283 Product Usage: The TomoTherapy treatment system is intended to be used as an integrated system for t he planning and precise delivery of radiation therapy, stereotactic radiotherapy, or stereotactic radiosurgery to tumors or other targeted tissues while minimizing the delivery of radiation to vital healthy tissues. The megavoltage x-ray radiation is delivered in a rotational, non-rotational, modulated (IMRT), or non- modulated (non-IMRT/3 dimensional conformal) format in accordance with the physicians prescribed and approved plan.
- Z-0288-2018 — TomoH(R) System, Model Number 1018284 Product Usage: The TomoTherapy treatment system is intended to be used as an integrated system for t he planning and precise delivery of radiation therapy, stereotactic radiotherapy, or stereotactic radiosurgery to tumors or other targeted tissues while minimizing the delivery of radiation to vital healthy tissues. The megavoltage x-ray radiation is delivered in a rotational, non-rotational, modulated (IMRT), or non- modulated (non-IMRT/3 dimensional conformal) format in accordance with the physicians prescribed and approved plan.
- Z-0289-2018 — TomoHDA(R) System, Model Number 1018286 Product Usage: The TomoTherapy treatment system is intended to be used as an integrated system for t he planning and precise delivery of radiation therapy, stereotactic radiotherapy, or stereotactic radiosurgery to tumors or other targeted tissues while minimizing the delivery of radiation to vital healthy tissues. The megavoltage x-ray radiation is delivered in a rotational, non-rotational, modulated (IMRT), or non- modulated (non-IMRT/3 dimensional conformal) format in accordance with the physicians prescribed and approved plan.
- Z-0507-2015 — TomoTherapy Treatment System with software versions 2.0.1 / 2.0.2 / 2.0.3/ (Hi:Art 5.0.1 / 5.0.2 / 5.0.3)
- Z-2239-2014 — TomoTherapy Treatment System, Model: Hi-Art, Catalog/Part Number: H-0000-0003, software versions 1.2.0, 1.2.1 and 1.2.2 (Hi-Art¿ 4.2.0, 4.2.1 and 4.2.2). .
- Z-2240-2014 — TomoTherapy Treatment System, Model: Hi-Art, Catalog/Part Number: H-0000-0003, software versions 2.0.0 and 2.0.1 (Hi-Art¿ 5.0.0 and 5.0.1). The TomoTherapy treatment system is intended to be used as an integrated system for the planning and precise delivery of radiation therapy, stereotactic radiotherapy, or stereotactic radiosurgery to tumors or other targeted tissues while minimizing the delivery of radiation to vital healthy tissues. The megavoltage x-ray radiation is delivered in a rotational, non-rotational, modulated (IMRT), or non-modulated (non-IMRT/three dimensional conformal) format in accordance with the physicians prescribed and approved plan.
Matched by K-number from FDA's Recall Enterprise System record (openFDA device/recallk_numbers) — these recalls explicitly list K121934.
Data sourced from openFDA. This site is unofficial and independent of the FDA.